Send Message

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations

Negotiable
MOQ
Negotiable
Price
18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations
Features Gallery Product Description Request A Quote
Features
Specifications
Nominal Voltage: 18/30 KV
Insulation: XLPE
No. Of Conductor: Single Core
Sheath: PVC Compound
Conductor Material: Bare Copper Class 2
Manufacturer: Shenzhen Chengtiantai
High Light:

xlpe power cable

,

medium voltage underground cable

Basic Infomation
Place of Origin: Shenzhen, China (mainland)
Brand Name: Chengtiantai
Certification: CE, ISO, IEC
Payment & Shipping Terms
Packaging Details: Iron wooden drum or as required
Delivery Time: 7/15 working days
Payment Terms: L/C, T/T
Supply Ability: 18,000 m per month
Product Description

18/ 30 kV Copper conductor XLPE ( Cross-linked Polyethylene )  Insulated PVC Sheathed cable

 

Introduction

 

stranded copper conductor - conductor screen of semiconducting compound - XLPE insulation - core screen of semiconducting compound - copper tape screen - separation tape - PVC sheath

 

suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground as well as for installation on cable trays for industries, switchboards and power stations.

 

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 0

  STANDER

International:IEC60502-2

National:GB/T 12706.1-2008

  CONSTRUCTION:

1. CONDUCTOR

– Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

2. CONDUCTOR SCREEN

– Inner semi-conducting coating

3. INSULATION

– Core insulation of cross-linked polyethylene (XLPE)

4. INSULATION SCREEN

– Outer conductive layer extruded and per-manently welded with the core insulation

Semi-conducting type
– Over the outer semi-conducting layer, a semiconducting tape must be used.

5. METAL SCREEN

– copper tapes helically with a minimum thickness of 0,1 mm.

Separator
– Over the screen as well as under outer sheath, a separating layer must be used (e. g. taping).

6. SHEATH

– Outer sheath of PVC compound

  CHARACTERISTICS

 

Construction characteristics

Conductor shape

Circular stranded (RM)

Lead free

Yes

Insulation

XLPE

Screen

copper tape

Material of bedding

Separation tape

Outer sheath 

PVC

Usage characteristics

Packaging

Steel Wooden Drum

Minimum installation temperature 

-20 °C

Max. conductor temperature in service 

90 °C

Short-circuit max. conductor temperature 

250 °C

Bending factor when laying 

20 (xD)

 

  18/ 30 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

No. of cores and nominal crosssection

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm²

kV

kV

mm

mm

mm

kg / km

A

A

Ω/km

1 x 50

36

18/ 30

8

2.0

32.6

1363

245

225

0.39

1 x 70

36

18/ 30

8

2.0

34.3

1614

305

275

0.27

1 x 95

36

18/ 30

8

2.1

36.1

1919

370

330

0.19

1 x 120

36

18/ 30

8

2.1

37.5

2203

430

375

0.15

1 x 150

36

18/ 30

8

2.2

39.3

2556

490

425

0.12

1 x 185

36

18/ 30

8

2.2

40.9

2934

560

480

0.10

1 x 240

36

18/ 30

8

2.3

43.3

3540

665

555

0.08

1 x 300

36

18/ 30

8

2.4

45.7

4191

765

630

0.06

1 x 400

36

18/ 30

8

2.5

49.1

5246

890

725

0.05

1 x 500

36

18/ 30

8

2.6

54.6

6561

1030

825

0.04

1 x 630

36

18/ 30

8

2.7

58.4

7906

1190

940

0.03


*Dimensions and specifications may be changed without prior notice.

 

  MEDIUM VOLTAGE CABLE TESTING

 

Routine tests:

Sample tests:

Type tests:

These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath

These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test

These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
- Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

 

  PACKING AND SHIPPING

 

Packing: steel wooden drum, other as required ; standard delivery length is 300 m

 

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 1

 

 

  Packaging & Delivery

 

Packaging details :

Delivery :

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 2

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 3

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 4

Steel Wooden Drums

Cable Drum In container 

shipped in 15 days after payment

 

  Cable Drum Data

 

CABLE DRUMS

D1=Flange Diameter(mm)

W=Useful Width (mm)

D2=Barrel Diameter(mm)

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 5

1000

700

500

1100

700

550

1200

700

600

1400

750

710

1600

900

900

1800

1120

1000

2400

1150

1300

 

 

  Delivery Port:

 

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 6

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 7

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 8

Port of Shenzhen 

Port of Hongkong 

Port of Guangzhou

 

  Our production in numbers

 

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 9

● Cable production started 1983
35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

100,000 m2 Production area
350 Will-trained employees
● Exported more than 22 countries
2 Manufacturing plant
1 R&D Center

200 Sets Of Testing Equipment

100 Testing Items
8 workshop
40 wire drawing machines
10 bunching machines
28 Extruder system
42 stranding machines
10 Braiding machines

 

  Shenzhen chengtiantai cable operates certified management systems compliant with:

 

 

Certificat

Information

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 10

ISO 9001:2008

Quality management systems

 

Certificat ISO 9001:2008
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 11

ISO 14001:2004

Environmental management systems

Certificat ISO 14001:2004

- Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 12

OHSAS 18001:2007

Assessment specification for occupational health & safety management systemsenvironmental management systems

Certificat OHSAS 18001:2007
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

 

  Manufacturing Process Of Medium Voltage Power Cable

 

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 13

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 14

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 15

1. copper rod

2. wire drawing

3. wire stranding

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 16

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 17

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 18

4.Triple Extrusion Insulation

5.Screening Process

6. outer covering Process

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 19

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 20

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 21

7. Sheath Marking

8. Packing

9. Partial discharge Inspection

 

  Some great shot on our manufacturing plant

 

Located in: Chengtiantai Industrial Park, Guangming New District, Shen zhen P. R. China 518106

 

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 2218 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 2318 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 2418 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 25

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 2618 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 2718 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 28

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 29

 

  Customer services:

 

18 / 30kV Outdoor Medium Voltage Power Cables For Power Supply Stations 30

  RECOMMENDED ORDERING PARAMETERS

  CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

  WARRANTY

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Recommended Products
Get in touch with us
Contact Person : Annie Chen
Tel : +8613670012325
Fax : 86-755-29886488
Characters Remaining(20/3000)